Mckinley t34 syringe pump instructions

Mckinley t34 syringe pump instructions
McKinley T34. Instruction Manual, pDF Adjusments Procedures Manual with schematics for I Alfa network awus036h power control driver · Mckinley t34 syringe driver. been referred to as the McKinley T34 syringe pump) is used safely. Staff in The service should have the manufacturer’s instruction manual on the use. Post navigation. ← MCKINLEY
T34™ Syringe Pump (3. rd. edition) LOCK ON DURATION (Prime and Load) Quick Reference Guide for Homecare. PAT999-103EN Rev. 04 Note: Instructions on the pump label are for reference only and do not reflect all . possible settings. Please, refer to the Directions For Use for full instructions.
Syringe driver pumps: T34™ 3rd edition models only – stop using the pump until updated instructions for use and BodyCommTM V3.0 software are released (MDA/2019/038)
The CME T34 syringe pump is a portable, battery operated device for delivering medication by continuous subcutaneous infusion (CSCI). Syringe pumps are a useful way of delivering
The T34™ is the safety standard in ambulatory syringe pumps – offering a comprehensive range of features designed to maximise safe and simple administration of medication, in both hospital and homecare environments.
Guidelines for use of McKinley T34 Preparing to Start a Patient on a Subcutaneous Infusion Via McKinley T 34 Prior to starting a syringe driver the practitioner needs to discuss its use with the patient and family. When setting up a new syringe pump, ensure a full body check is undertaken to ensure no existing infusion is in situ.

The T34™ Ambulatory Syringe Pump is the safety standard in ambulatory syringe pumps, offering a comprehensive range of features designed to maximise safe and simple administration of medication, in both hospital and homecare environments. Main Features: • Lightweight, compact and fully ambulatory • Powered by a 9V PP3 battery • Syringe recognition of commonly used syringe brands (2ml
Niki t34 syringe pump: continuous subcutaneous infusion management. Page 6 of 8 Gynaecology . 7. Complete the medication additive label and place on the extension line. Do not put the label on the syringe or any part of the pump (this alters the syringe diameter and the volume will be miscalculated by the pump). 8. Document the date of
o The pump has been designed to be as safe as possible to handle; however, care should be exercised to avoid trapping of fingers or other body parts in the mechanism. o The T34™ syringe pump system should be operated within a temperature range of -15°C (-59°F) to +45°C (+113°F). Operation at temperatures outside this range may affect
This policy and procedure for the use of the CME McKinley T34 Syringe Driver for Adults in Palliative Care has been written and adapted, with the kind permission, from guidance produced by the following organisations: McKinley T34 Ambulatory Syringe Pump Operation Manual (2011)
Preferred Syringe when using the McKinley T34 Syringe Pump. 6 Equipment required. 7 Bolus Dosing 8 Procedure for setting up a T34 syringe Pump 8-10 Changing the set up 11 DATIX reporting adverse events 11 Starting an Infusion. 12 Monitoring a Pump in progress 13 McKinley T34 pump Alarms and actions / responses. 14
The McKinley® T34 syringe driver/pump is used to deliver drugs at a predetermined rate via the subcutaneous route over a 24 hour period; A maximum of 3 compatible drugs can be mixed in a syringe for administration via this route
The McKinley T34 offers the functionality of larger syringe pumps packaged in a small, lightweight, robust, ergonomic, battery powered ambulatory device. T34 is a safe, simple and reliable syringe pumpthat can deliver infusions for a wide range of clinical applications allowing small volumes to be administered with significant levels of
McKinley T34 Syringe Pump 1. McKinley T34 Syringe Pump Prepared by: Devanshu Patel Enrol No. 110423117006 2. Syringe Pump • A syringe driver or syringe pump is a small infusion pump (some include infuse and withdraw capability), used to gradually administer small amounts of fluid (with or without medication) to a patient or for use in chemical and biomedical research. • The most popular
A syringe driver is a portable battery powered device that administers medication subcutaneously over a chosen period of time. A syringe containing medication is attached to the driver, which pushes the plunger forward at a controlled rate. At Nurse Maude the T34 syringe driver is used. All T34 syringe drivers owned by Nurse Maude are locked on
Service & Repair Manual 19/06/2007 T34 Syringe pump 1. Barrel Clamp arm (detects Syringe size/width of barrel) 2. Syringe ear/collar sensor (detects correct loading of syringe collar) 3. Plunger sensor (detects correct loading of syringe plunger) 4. 4 line LCD display (back light (can be …

McKinley T34 Syringe Driver Training Clinical Training


McKinley T34 Syringe Driver Guidelines for Adult

McKinley T34 Syringe Pump Page 2 of 6 What is a syringe pump? A syringe pump is a small, portable, battery powered digital machine. Attached to the pump is a syringe containing the prescribed medication. The syringe on the pump will need to be changed every 24 hours with the prescribed medication.
A McKinley T34 syringe pump is a portable battery-operated infusion pump weighing approximately 210g (excluding the battery) and measuring 169mm by 53mm by 23mm. The McKinley T34 model is calibrated in ml per hour. All T34 pumps for palliative care are set up to deliver the syringe contents by continuous subcutaneous infusion over a 24 hour
T34 ambulatory syringe pump is a lightweight, compact and fully ambulatory syringe pump with motor driven linear actuator, pulsed motion. The T34 provides safe and simple administration of medication, in both hospital and homecare environments.
06/07/2015 · Cool idea for the workshop!! FROM THE ENGINE FROM A WASHING MACHINE. – Duration: 10:15. Home Workshop Recommended for you
Setting up a Syringe Driver McKinley T34 Revision Mar 2017 1 / 4 Introduction Equipment Clinically clean tray containing the prepared drug Syringe pump Battery (P P3 size, 9 volt alkaline) Plastic peripheral cannulas (e.g. 24 G) and microbore extension set (100 cm) with needle-free Y connector injection site 9 (o r 100 cm winged infusion set)
Western Trust Policy for Use of the CME McKinley T34 Ambulatory Syringe Pump for Adult Palliative Patients Page 4 of 34 1. INTRODUCTION 1.1 This policy has been designed to provide evidenced based guidance on the safe use of the CME McKinley T34 ambulatory syringe pump (McKinley T34
Section 1 Setting up the syringe driver The McKinley T34 model is calibrated in ml per hour. All T34’s for palliative care are set up to deliver the syringe contents by continuous subcutaneous infusion over a 24hour period only. Choice of Syringe The McKinley T34 may be used with most brands of syringe. Dickman (2005) recommends a
11.6. Physical features chart of the McKinley Syringe Pump can be found at Appendix 7. 12 Setting up the Pump 12.1. For instructions on setting up the McKinley Syringe Pump please see appendix 1 13 Priming of Lines 13.1. The line must be no greater than 0.5mls in order for the amount used to purge/ prime the line to be negligible. 13.2. Under
Laboratory syringe pumps for precise infusion and withdrawal with advanced programming and automation. Along with computer interface capabilities. For applications involving research, laboratory and industrial uses.


CME T34 guidelines; CME T34 guidelines. The CME T34 Syringe Pump guideline is an update to guidance first produced in 2011 by NHS Education for Scotland (NES) on use of hte McKinley Syringe Pump. The udpate has been produced in consultation with practitioners to support the delivery of consistent, high quality care through best practice in the
NHSGGC CME T34 Syringe Pump Competency – Primary Care 290915 Page 10 of 16 Appendix 1 PREPARATION AND SETTING UP OF CME T34 SYRINGE PUMP – Additional Notes 1. CHOICE OF CANNULA The Saf-T-Intima (single lumen) 22g cannula is the needle free s/c cannula of choice as:- • Needle stick injury is reduced
McKinley T34 Syringe Pump Guidelines for use in Adult Palliative Care Patients: Guideline for use in Greater Glasgow areas (2009). NHS Greater Glasgow & Clyde. Syringe Pump Guidelines CME McKinley T34 (ml/hour): for use within Argyll and Bute CHP and Clyde. NHS Greater Glasgow & Clyde and NHS Highland. 4 Guidelines for the use of the T34TM Ambulatory Syringe Pump by CME Medical for adults …
All models of T34 ambulatory syringe pumps – updated cleaning advice and maintenance requirements due to the risk of fluid ingress (MDA/2019/030)
The T34 syringe pump is a small, lightweight ambulatory infusion pump which offers flexibility and reliability. Effortless transition between hospital and home care requirements is the core of the T34 syringe pump.


07/03/2015 · Claire Britton, Specialist Nurse Practitioner from Sobell House’s Community Team, demonstrates how to set up the T34 syringe driver.
These McKinley T34 syringe driver training courses focus on the safe set up and use of these subcutaneous infusion pumps.
Deliver Syringe Infusion Anywhere. Provide complete small-dose infusion therapy safely and economically wherever your patients receive care. The T34™ ambulatory syringe pump from CME contains many features of larger syringe pumps in one highly compact, lightweight design.
Mckinley T34 Syringe Pump Children Resource Pack 1689-19066.doc 5 5 Shropshire Community Health NHS Trust 3.1 Choice of Syringe The recommended syringes to use with the McKinley T34 syringe pump is Becton Dickinson(BD) Plastipak or Braun Omnifix and only these must be used.
McKinley Medical UK Ltd. Ambulatory Syringe Pump Instruction manual McKinley T34, June 2005 NHS Greater Glasgow & Clyde. McKinley T34 Syringe Pump Guide-lines for Use in Adult Palliative Care Patients. January 2009 Introducing the McKinley T34 Syringe Pump into the Isle of Man McKinley T34 syringe pump
McKinley T34 Syringe Pump user pocket reference guide. (Appendix 2) McKinley T34 Syringe Driver Duracell® brand 9-volt (6LR61) battery 2x Silhouette cannula 2x Semi permeable dressings 2 of each 10ml / 20ml Luer-Lock syringes (extras available from ACU Haem / Onc Dept. 2 x Additive Labels (white) Disposable disinfection wipes

Policy and Procedure for the use of the CME MEDICAL

Appendix C McKinley T34 Syringe Pump Patient Information Leaflet 35 Appendix D Nursing Record of Syringe Driver Checks 37 Appendix E Audit Criteria for Syringe Driver Policy and Guidelines McKinley T34 38 . Syringe Driver Policy V3 – 4 – August 2015 1 INTRODUCTION 1.1 This policy sets out key principles and guidance for the management of subcutaneous infusions via syringe drivers. It supports
1. Remove the McKinley T34 Syringe Pump & accessories from the packaging and inspect for damage during shipment or storage. WARNING: Do not use T34 if there are any obvious signs of damage. Return for inspection by authorised service personnel. 2. Make sure you have the following items: • McKinley T34 Syringe Pump • Operation Manual
The medical infusion device that this guidance refers to is the McKinley T34 syringe pump which was launched in the United Kingdom in 2005. What is the McKinley T34 Syringe Pump? The McKinley T34 syringe pump is a small, lightweight, battery powered, ambulatory syringe pump which has a Liquid Crystal Display (LCD) screen.
The T34 syringe pump can be easily concealed beneath clothing in a shoulder holster and combination belt. A compact lockbox is provided to protect the Pump from damage and/or tampering with either the pump or the syringe. T34 offers 3 point syringe detection enabling the pump to identify all commonly used (or programmed) syringe brands. This
Using the T34 Syringe Driver • The T 34 in Sheffield is programmed to use a 30ml Luer-Lok BD syringe ONLY • Check service expiry date • The standard delivery of medication in Sheffield is programmed for 24hours • Two registered nurses required to set up the syringe driver • Familiarise yourself with the Policy & Procedure • Complete the T34 competency form . Maintenance and
Syringe Pumps: Rule of thumb is if you can push or pull the syringe with your hand, then we have a pump that can push or pull the syringe. To reduce viscosity, you can utilize our Syringe Heater Kit. Warming up the fluid may reduce the viscosity. Peristaltic Pumps: Rule of thumb is if the liquid freely flows by itself, the peristaltic pump can
which the syringe pump was loaned to, to cover the cost of any lost pumps. The cost of replacing pumps lost to the community may be recovered from the ward from which patient was discharged from. Please refer to WSFT policy PP(17) 024 (section 6). McKinley T34 syringe pump and plastic lockbox. This is obtained through the Medical
T34 Syringe Pumps staff and pharmacists, who are delivering subcutaneous medication for palliative care patients by bolus or using the T34 Syringe pump by CME

GUIDELINE FOR THE USE OF THE McKINLEY T34 SYRINGE PUMP

NiKi T34L Infusion Syringe Pump Progress Healthcare. T34 Syringe Driver 12 Syringe driver equipment 5.3 Syringe drivers must be fit for purpose and manufactures instructions and the Royal Marsden Manual of Home Hospitals & Services Information for Health Professionals ICU Registrar Handbook Air Retrieval Service Power during Transport. Syringe
7.0 Indications for Using a McKinley T34 Syringe Driver 5 8.0 Information For Patients And Carers 6 9.0 Prescribing and Administering Drugs by Subcutaneous Infusion 6 10.0 Drug Stability and Compatibility 7 11.0 Choice of Site for using Syringe Driver 7 12.0 Care Of Site 7 13.0 Setting up the McKinley T34 syringe pump 8

Safe practice in syringe pump management Nursing Times


McKinley T34 Syringe Pump wwl.nhs.uk

Setting up a CME medical T34 Syringe Driver


Policy and Protocol for the use of the CME McKinley T34

Guidelines for the Use of the CME T34 Syringe Pump for

PROCEDURE FOR THE USE OF McKINLEY T34 SYRINGE DRIVER

T34 CME Medical

SYRINGE DRIVER POLICY AND STANDARD OPERATING


Essential Syringe Driver Training for T 34

Setting up a Syringe Driver McKinley T34

1 thought on “Mckinley t34 syringe pump instructions”

  1. A syringe driver is a portable battery powered device that administers medication subcutaneously over a chosen period of time. A syringe containing medication is attached to the driver, which pushes the plunger forward at a controlled rate. At Nurse Maude the T34 syringe driver is used. All T34 syringe drivers owned by Nurse Maude are locked on

    McKinley T34 Syringe Pump Resource Pack